50 Ecton Lane Sywell Northampton NN6 0BA
Variation of condition 2 (approved drawings) of planning permission reference: NW/22/00385/FUL to allow for a change in facing materials on the main dwelling and to add 2 dormer windows in the roof of the garage.
139 Doddington Road Wellingborough NN8 2LY
Variation of condition 2 (approved plans) of planning permission reference NW/22/00775/FUL to change the flat roof of the side extension to a mono pitch roof
3 Little Lane Wollaston Wellingborough Northamptonshire NN29 7SQ
Application for variation of a condition 2 (plans) following grant of planning permission reference WP/20/00647/FUL to rectify incorrect drawings that were submitted in relation to the approved planning permission reference WP/20/00647/FUL. Drawing numbers 58-20-01 & 02A, portrayed the existing roof profile with a steeper pitch and a higher ridge than is actually the case. The proposed structure has been built in accordance with the approved drawings, but due to the existing roof being lower than previously indicated, has resulted in the apex of the extension extending 0.45 metres above that of the existing. The extension is to be built in accordance with drawing numbers 58-20-111 & 58-20-222
35A Irthlingborough Road Finedon Wellingborough Northamptonshire NN9 5EH
Variation of condition 2 of planning permission reference WP/20/00141/FUL. Substitute drawing nos. 6835-PL03- Proposed Site Plan, 6835-PL04A- Unit 1 Proposed floor & roof plans, 6835-PL05A Unit 1 Proposed Elevations with drawing nos. 6835/PL03G Proposed Site Plan, 6835/PL04D Units 1&4 Proposed Floor & Roof Plans, 6835/PL05E Units 1&4 Proposed Elevations. The changes proposed subdivide Unit 1 to create an additional unit (Unit 4) with changes to the fenestration but no change to the overall floorspace. Addition of ATM, Plant and Noise Impact Assessment in relation to Unit 1
31 - 33 Stanley Road Wellingborough Northamptonshire NN8 1DY
Variation of condition 2 of planning permission ref: WP/17/00721/FUL to substitute previously approved plans - Planning Layout (drawing reference: OL/1003-001 Rev D) with Planning Layout (drawing reference: OL/1003-001 Rev J). The amendments proposed as part of this application comprise of the internal reconfiguration to locate both bedrooms at first floor level (Plot 7). The application also seeks retrospective amendments to the built envelope of Plot 7 due to the development not being constructed in accordance with the approved plans. These amendments include: Minor increase in the building footprint. Alterations to the rear/side elevation and roof. Increase in the height of the rear facade and changes to the rear roof pitch from 45 degrees as approved to 30 degree.